See also
Battery type | LITHIUM-ION |
---|---|
Max. Input Voltage | 50V DC |
Max. Charge Voltage (battery) | 29.4V |
Nominal Voltage | 26.46V |
Charging Method | Constant Current / Constant Voltage |
Max. Charge Current | 8A |
Charging taper Current | 1800mA +/- 100 mA |
Max. Discharge Current | 14A/1ms |
Typ. Discharge Current | 2.8A (7A/2ms / 2A/18ms every 20ms) |
Typ. Capacity | 30Ah |
Minimum Capacity | 29.5Ah |
Impedance (1kHz) | Approx. 100 mOhm |
Cycle Life | Min. 300 ≥ 20.65Ah (70% of the capacity at 25°) Expected 1000 ≥ 70% of the capacity at 25°C |
Current use in Active Mode | Max. 3.5mA (battery electronic) |
Current use in Stand-by Mode | Max. 850μA (battery electronic) |
Current use in power down Mode (V<2.5V per cell) |
Max. 50μA (battery electronic) |
Operating Temperature | For Charging: 0 to + 50°C For Discharge: 0 to + 50°C The battery is thermal protected and interrupts charge / discharge when temperature limits violated |
ESD (EN 61000-4-2 / 12.2009) | 8 kV air discharge 4 kV contact discharge |
Energy | 396 Wh |
Pepper can be used while it is plugged in with the adapter. But the battery will charge only if Pepper is powered off and plugged to its adapter.